Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableThe temperature was right at the loading dock, but what happened during transport?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableThe temperature was right at the loading dock, but what happened during transport?
Item number 52-DEF2

Dual-Scale Urea Refractometer for Urea-Based Diesel Exhaust Fluid (DEF)

5.763 SEK

In stock

Refractometer for Selective Catalytic Reduction (AdBlue)

Request a quote 52-DEF2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments for professionals since 2002
  • Call us +46 8 753 00 04

Category:

Description
Since 2010, stricter requirements have been imposed on diesel-powered vehicles to comply with new, more stringent EPA emission guidelines. Vehicle manufacturers use, among other technologies, Selective Catalytic Reduction (SCR) to meet these new requirements.


Selective Catalytic Reduction systems utilize liquid urea, a nitrogen-based compound, to treat diesel exhaust in a specialized catalyst. This liquid is known as Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of aqueous urea in demineralized water. This is injected into the hot exhaust gases as a fine mist, converting urea into ammonia, which in turn converts harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.


The Palm Abbe is the best defense against diluted DEF.


The correct concentration of Diesel Exhaust Fluid (DEF) is critical for reducing harmful nitrogen oxide emissions and extending the lifespan of SCR components. An uneven concentration of as little as +/- 0.8% will prevent the DEF liquid from performing its function. DEF dilution or contamination can affect system performance and maintenance costs. The greatest contamination threat is water dilution, but without the right tool, it is nearly impossible to know if a DEF supply has been diluted.


The Palm Abbe DEF-202 provides concrete results in just a few seconds.


The Misco Palm Abbe DEF-202 refractometer is an ideal method for testing DEF liquid to ensure it has the correct concentration and has not been diluted or tampered with. It takes only a few drops of DEF and a couple of seconds to perform a test, and the result is accurate to +/- 0.1% urea concentration.
Specification
Since 2010, stricter requirements have been imposed on diesel-powered vehicles to comply with new, more stringent EPA emission guidelines. Vehicle manufacturers use, among other technologies, Selective Catalytic Reduction (SCR) to meet these new requirements.


Selective Catalytic Reduction systems utilize liquid urea, a nitrogen-based compound, to treat diesel exhaust in a specialized catalyst. This liquid is known as Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of aqueous urea in demineralized water. This is injected into the hot exhaust gases as a fine mist, converting urea into ammonia, which in turn converts harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.


The Palm Abbe is the best defense against diluted DEF.


The correct concentration of Diesel Exhaust Fluid (DEF) is critical for reducing harmful nitrogen oxide emissions and extending the lifespan of SCR components. An uneven concentration of as little as +/- 0.8% will prevent the DEF liquid from performing its function. DEF dilution or contamination can affect system performance and maintenance costs. The greatest contamination threat is water dilution, but without the right tool, it is nearly impossible to know if a DEF supply has been diluted.


The Palm Abbe DEF-202 provides concrete results in just a few seconds.


The Misco Palm Abbe DEF-202 refractometer is an ideal method for testing DEF liquid to ensure it has the correct concentration and has not been diluted or tampered with. It takes only a few drops of DEF and a couple of seconds to perform a test, and the result is accurate to +/- 0.1% urea concentration.
Reviews (0)

There are no reviews yet.