The meeting room feels fine when the meeting starts. After an hour the air is heavy, people lose focus and someone opens a window. Yet the thermostat shows 21 °C the whole time. The same thing happens in control rooms, laboratories and staff areas: the temperature looks right, but the air is stale. Without measurement data, it becomes one opinion against another.
Three channels in one unit
The TandD 56-RTR-576-S is a wireless logger that measures carbon dioxide, temperature and relative humidity at the same time. Carbon dioxide is measured in the range 0 to 9 999 ppm. Temperature and humidity are measured with an external high-precision probe (SHA-3151) with a range of −25 to +70 °C and 0 to 99 %RH. Accuracy is ±0.3 °C and ±2.5 %RH at 15–35 °C and 30–80 %RH. The logger has an automatic calibration function for CO₂, so the measurement stays stable over long operating periods without manual adjustment.
What it solves
CO₂ is not a toxic gas at these levels, but it works as an indicator of how much air is actually being exchanged relative to the number of people in the room. A normal office is often around 400–1 000 ppm. At around 1 000 ppm many people start to feel tired, and at 2 000 ppm the discomfort is obvious. The logger stores up to 8 000 data points with a selectable interval between 1 second and 60 minutes. This shows when the level rises, how quickly, and whether the ventilation is actually keeping up.
Three situations where it is used
Offices and conference rooms: Measure over a normal working week and compare occupied and empty hours. The curve shows whether the ventilation needs to be adjusted, or whether it simply needs to run at the right times.
Schools and health centres: Rooms with many people and short breaks fill up quickly. The logger shows when airing the room or adjusting the ventilation actually makes a difference. It also provides documentation when dealing with property owners.
Production halls and laboratories: Where temperature and humidity are already critical to the process, you get CO₂ as a third channel from the same location. The range is about 150 metres line of sight, and the alarm output can send a signal to other equipment when a limit value is exceeded. Configuration is done via a mobile app using Bluetooth 4.2 BLE.
Why it pays off
Ventilation that is too weak costs you in fatigue and reduced concentration. Ventilation that runs too hard costs you in energy. Without measured values, you are guessing in one direction or the other. With a logger, operation can be adjusted to actual need, and a corrective action can be followed up with the same measurement before and after. A single unit with three channels also replaces separate instruments and provides data you can present in a work environment discussion or an inspection.
If you need documentation that shows what the air is really like, rather than how it feels, this is a reasonable starting point.