Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cable
Item number 56-TR-71NW

TandD Logger for temperature, 2 channels (1 internal + 1 external, or 2 external), wired Ethernet/LAN. -60 to +155 °C depending on probe/sensor. Cloud connectivity

2.481 SEK

In stock

TandD Logger for temperature, 2 channels (1 internal + 1 external, or 2 external), wired Ethernet/LAN. -60 to +155 °C depending on probe/sensor. Cloud connectivity

Request a quote 56-TR-71NW

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments for professionals since 2002
  • Call us +46 8 753 00 04

Category: , , , ,

Other models in the series 4

Description

The 56-TR-71NW is TandD’s Ethernet-connected 2-channel temperature logger — simply connect a network cable directly to the logger, and it will automatically start uploading data to the T&D WebStorage Service cloud or an internal PC running T&D Data Server. PoE support (IEEE 802.3af) means a single cable is sufficient for both power and network connectivity.

The logger is supplied with 2 thermistor probes TR-0106 on cable — ready to be placed directly at the measurement point. The measuring range is 0 to +55 °C with standard probes, or up to -60 to +155 °C with fluoropolymer-coated alternatives. The wired Ethernet connection is advantageous in environments where WiFi coverage is absent or unreliable (basements, concrete buildings, factory floors).

Features

  • 2 external thermistor probes TR-0106 included
  • External probe measuring range: -60 to +155 °C (depending on probe)
  • Internal probe measuring range: -40 to +110 °C
  • Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C otherwise
  • Wired Ethernet 10/100 Mbps (RJ45)
  • PoE IEEE 802.3af — power + network via a single cable
  • HTTP (proxy supported), DHCP, DNS
  • 16,000 data point memory
  • 15 fixed logging intervals + 15 upload intervals (1 min to 24 h, or manual)
  • Battery life up to 1.5 years at 12-h upload or OFF
  • USB 2.0 Mini-B for PC configuration
  • Built-in LCD with rotation of current values

Specification

Measurement channels Temperature 2 channels — thermistor (external, on cable) + 1 internal sensor
External measurement range -60 to +155 °C (depending on probe)
Internal measurement range -40 to +110 °C
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C (other)
Resolution 0.1 °C
Logging capacity 16,000 data points
Network 10 Base-T / 100 Base-TX (RJ45)
Protocols HTTP (proxy supported), DHCP, DNS
Other interfaces USB 2.0 Mini-B
Power supply 2 × AA alkaline LR6 / Ni-MH, USB bus, AC adapter 56-AD-05A2/C2, or PoE IEEE 802.3af
Battery life approx. 10 days (1 min logging), approx. 1 year (1 h logging), approx. 1.5 years (12 h / OFF)
Dimensions 58 × 78 × 26 mm
Weight approx. 55 g
Operating environment -10 to +60 °C, max 90 % RH non-condensing

Included

  • 56-TR-71NW logger
  • 2 × External temperature probe 56-TR-0106 (one per channel)
  • 2 × AA alkaline batteries
  • USB Mini-B cable 56-US-15C
  • Registration code label for T&D WebStorage Service
  • Manual set with warranty certificate

Applications

The 56-TR-71NW is suitable for fixed installations with access to the company’s Ethernet network: server rooms (PoE installation ideal), industrial environments, hospitals, laboratories, food production. For WiFi instead of LAN, see 56-TR71A2 (incl. WPA2-Enterprise and Vaccine Mode). For combined T+RH, see 56-TR-72NW. For thermocouples, see 56-TR-75NW.

Additional information
Product type

Measures

Temperature

Communication

Wired Ethernet

PDF (1)