Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cable

A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way Through

Published 19 November 2026 at 00:14

An inspector put the thermometer into the product at ten o’clock and noted 74 °C. The customer files a complaint about the batch the following week, and no one can show what happened in the middle of the oven, cold room or autoclave during the hours when no one was measuring. A manual spot check is a single moment. It says nothing about the progression, and the progression is usually what you are asked to prove.

ETI ThermaData® temperature logger in stainless steel with penetration probe Ø4.5 x 150 mm. Withstands -20 to +125°C. Waterproof. Connection via USB-C

What it is

The ETI ThermaData in stainless steel is a standalone temperature logger with a fixed penetration probe, Ø4.5 x 150 mm. The housing is made of food-grade 316 steel and meets IP66/67, so it withstands water, moisture, impacts and cleaning. The measuring range is -20 to 125 °C, the resolution 0.1 °C and the accuracy ±0.5 °C. The memory holds 16,000 readings, and the interval can be set from one second to 255 minutes. You unscrew the end cap, connect the supplied USB-C cable and read the data out to your computer.

Which problems it solves

The logger replaces notes from memory and spot checks with an unbroken curve. You set high and low alarm limits, choose to start by software, temperature or time, and after download you get an automatic PDF summary. With a one-minute interval the memory lasts just over eleven days, and with five minutes almost two months. A user ID of up to 31 characters means each run can be linked to a batch or a checkpoint.

How it is used in practice

In food production, the logger and its probe are placed in a product or a package and follow it through heat treatment and cooling. The curve shows how long the core actually stayed above the critical temperature, not just what the oven display claimed.

In pharmaceutical and laboratory operations, it is used to map heating cabinets, drying ovens and washer-disinfectors up to 125 °C. It is a way to show that the process holds its temperature over time and not just at a single check.

In quality and maintenance, it is placed in a truck, a corner of a cold or freezer room, or a hot transport container to investigate where and when the temperature deviates. In investigation and complaint work, it is often the first time anyone gets to see the whole progression.

Why it pays off

The cost of a scrapped batch or a failed audit quickly exceeds the price of the logger. You also save time. Nobody has to walk around taking readings at regular intervals, and the report takes a few minutes to produce instead of an afternoon of handwritten records. If you need formally traceable values, a three-point UKAS certificate is available as an option. Because the logger is sealed and robust, it can be reused for many years in environments where simpler models would fail.

If you need documented temperature rather than a single figure, this is a reasonable tool to start with. See specifications and options for the stainless steel ThermaData.

Read more

More news