Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cable

TVOC is a sum, not a single substance, which is why formaldehyde has its own sensor

Published 26 August 2026 at 02:27

A TVOC value looks like an air quality measurement. It is actually a sum: the instrument adds up the contributions from a large family of volatile organic compounds and displays a single number. The number indicates that something is being emitted into the air — but not what it is, nor how serious it is.

Two rooms can have the same TVOC level yet be completely different. One may smell of fresh paint, while the other has flooring that emits formaldehyde. That is why this instrument measures two things simultaneously: the broad sum, and the specific substance for which regulatory limits actually exist.

VFM200 maetare foer VOC och formaldehyd med samtidig visning

What it is

VFM200 — a portable meter that displays TVOC and formaldehyde in real time.

  • TVOC and HCHO simultaneously on a backlit display
  • The formaldehyde sensor is a fuel cell — electrochemical and substance-specific
  • Two selectable units: ppm or mg/m³
  • Adjustable audible and visual alarms for high and low values
  • Automatic shutdown, rechargeable battery with AC adapter

Why two sensors instead of one

A broad VOC sensor responds to almost all organic compounds. Acetone, toluene, xylene, benzene, solvents from paint and adhesives, exhaust fumes, cleaning agents, cooking odors — all contribute to the same number. This makes TVOC an excellent indicator: the value rises when something is happening and falls when you ventilate. However, because you do not know what is contributing, you cannot compare it against a limit value for a specific substance.

Formaldehyde is exactly such a specific substance. It is common in panel materials, adhesives, surface treatments, and new furniture, it continues to emit for a long time after installation, and it is one of the few indoor air substances for which most people have a specific limit value to comply with. A dedicated fuel cell sensor responds to the formaldehyde itself, rather than letting it disappear into the total sum.

Together, the two provide something neither can do alone: TVOC tells you that something is being emitted and when it increases, while the formaldehyde value tells you how much of the substance you need to be able to report.

The units, and why both exist

Limit values are published in both ppm and mg/m³, depending on the source and context. Converting between them is not difficult, but it requires the substance’s molar mass and a temperature — and a conversion done in your head or in an app is an extra place where errors can occur. The fact that the instrument can display the unit in which your guideline value is written eliminates that step entirely.

How to measure so the number means something

Emission depends on the conditions, not just the material. It is highest in a closed, warm, and still room and drops quickly when you ventilate. A measurement taken with the window slightly open may therefore look calm in a problematic room, while a measurement after a night of still air shows the opposite.

The useful approach is therefore to measure in the same way every time: same time of day, same ventilation setting, preferably in the morning before the room has been opened up. This makes the values comparable between rooms and over time — and it is the comparison that shows where the source is and whether the action helped.

Three typical use cases

  • New builds and renovations: monitoring emissions from flooring, panel materials, adhesives, and paint after moving in.
  • Offices and schools: investigating complaints about odors, headaches, and stuffy air.
  • Hotels and facilities: checking after furnishing or surface treatment, before the rooms are put into use.

Why it is worth it

Complaints about indoor air are difficult to handle precisely because they lack numbers. One person thinks it smells, another does not, and the investigation becomes a series of measures tried one by one — often with ventilation as the first and most expensive guess.

Two measurement values, taken in the same way in several rooms, make the question manageable: is there an elevation, where is it highest, and did it go down after you did something. It is rarely the single measurement that is valuable, but rather that the discussion has a basis to work around.

Read more about the VFM200 meter for VOC and formaldehyde →