Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cable

Differential Thermometer — In Heat and Cold, the Answer Is Rarely a Temperature, But the Difference Between Two

Published 22 August 2026 at 11:55

Ask a maintenance technician what temperature a heat exchanger, cooling coil, or radiator circuit should maintain, and the answer almost always starts with “it depends.” Outdoor temperature, load, setpoint, and season all shift the absolute values. What can be assessed, however, is the difference between supply and return — how much heat was actually released or absorbed along the way. That figure tells you something about the system regardless of what the absolute numbers happen to be on any given day.

Comark KM340 industrial differential thermometer with dual inputs for Type K

What it is

The Comark KM340 is a handheld industrial thermometer with dual inputs for Type K thermocouples, with a measurement range of −50 to +1300 °C. It displays T1, T2, and the difference between them, features selectable resolution of 0.1° or 1°, switches between °C and °F, and includes a Hold function that freezes the reading as well as MAX memory that records the highest measured value. A protective rubber case with a stand is included, and the connection uses a mini-DIN connector — the same standard used by a wide range of sensors.

The problem it solves

Two sensors, one instrument, one clock. You can, of course, measure supply and return with two separate thermometers and calculate the difference in your head, but this approach has three drawbacks that differential measurement avoids. The measurements are not taken simultaneously, which matters in a system where temperatures are fluctuating. They are made with two instruments, each having its own deviation. And the subtraction is done mentally or on a scrap of paper, which is where calculation errors occur.

With both sensors connected to the same instrument, the difference is read directly, at the same moment, by the same electronics. This is also why the difference is often more reliable than the individual values — the instrument’s own systematic deviation acts in the same direction on both channels and therefore affects the difference significantly less than it affects the absolute values.

What you are actually looking at:

  • Supply and return in a heating circuit: a ΔT that is lower than normal indicates that the circuit is not releasing its heat — air in the system, flow that is too high, a blocked radiator, or a misadjusted valve.
  • Across a cooling coil: a changed ΔT points to a dirty surface, ice formation, or insufficient refrigerant, long before the room temperature begins to deviate.
  • Across a filter or fan: the temperature difference combined with flow rate gives a picture of whether the unit is operating as intended.

The presence of MAX memory is linked to how troubleshooting works in practice: many processes have a peak that occurs when no one is looking at the display — during startup, during defrosting, or during a load change. An instrument that retains the highest value allows you to measure during the process and read the result afterwards.

One prerequisite worth mentioning: a difference is only as good as the two sensors. If ΔT is to be assessed in tenths of a degree, the sensors should be of the same type and preferably identical — and installed equivalently, with the same contact against the pipe and the same insulation. Two different sensors in different mounting situations can yield a difference that reflects the installation more than the medium.

Three typical use cases

  • Heating and HVAC: supply and return temperatures on circuits, radiators, and heat exchangers.
  • Cooling and air conditioning: checking the cooling coil’s output and temperature drop across the evaporator.
  • Process and industry: temperature difference across equipment where a measurement range up to 1300 °C is required.

Why it pays off

The most common cost in heating and cooling systems is not breakdowns but silent inefficiency. A circuit that does not release its heat, a partially blocked coil, or a system with air in it continues to function — just less efficiently and with higher energy consumption — until someone measures it. ΔT is the parameter that reveals this, and it requires neither disassembly nor downtime.

Add in the troubleshooting time. Without differential measurement, diagnosis often consists of comparing absolute numbers against what you remember them to be — which is a weak basis. With ΔT, you have a metric that can be compared between occasions, between circuits, and against manufacturer specifications, making it possible to state what has changed instead of guessing.

Read more about the Comark KM340 differential thermometer →

More news

All news