Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature was right at closing time, but what happened during the night?See inside the engine block, duct or machine without taking anything apartSurface temperature at goods reception can be measured in three seconds without touching the productThe Dishwasher’s Display Temperature Doesn’t Tell You What the Plate Actually GetsReflections on shiny metal surfaces often hide the defect you are looking for, but a polarized digital microscope reveals itA Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature was right at closing time, but what happened during the night?See inside the engine block, duct or machine without taking anything apartSurface temperature at goods reception can be measured in three seconds without touching the productThe Dishwasher’s Display Temperature Doesn’t Tell You What the Plate Actually GetsReflections on shiny metal surfaces often hide the defect you are looking for, but a polarized digital microscope reveals itA Spot Check Shows Only One Moment: How to Document Core Temperature All the Way ThroughWhen a temperature measurement takes 0.4 seconds, it also gets done at every checkHow to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessing

ETI Precision Plus PT100 Reference Thermometer with 5-Point UKAS Certification: When a Ø4 mm 1/10 DIN Class A Pt100 Liquid Probe Delivers ±0.03 °C Accuracy — Good Enough to Calibrate All Other Thermometers in Your Business

Published 15 July 2026 at 05:46

ISO 9001, HACCP, GxP pharmaceuticals, GMP manufacturing — all these quality systems require that measuring instruments are REGULARLY VERIFIED against a reference. The fundamental principle: you cannot verify an instrument with the same instrument that is to be verified. The reference must be MORE PRECISE.

Common practice: send Thermapens and other routine thermometers to an external calibration lab once a year. Cost: 1,500–3,000 SEK per instrument per occasion. For a business with 10 thermometers, this amounts to 15,000–30,000 SEK per year.

Alternative: buy ONE PRECISION REFERENCE THERMOMETER and calibrate internally. The reference is sent to the lab only every 2–3 years. All other instruments are verified daily/weekly internally against the reference. The Precision Plus PT100 is designed for this role.

1/10 DIN Class A — what it means

PT100 thermometers are classified according to IEC 60751 based on RESISTANCE TOLERANCE at 0 °C and across the entire measurement range:

  • Class B (standard quality): ±0.30 °C at 0 °C, ±0.80 °C at 100 °C. For industrial routine measurement.
  • Class A (precision quality): ±0.15 °C at 0 °C, ±0.35 °C at 100 °C. For research labs.
  • Class 1/3 DIN B: ±0.10 °C at 0 °C.
  • Class 1/5 DIN B: ±0.06 °C at 0 °C.
  • Class 1/10 DIN B: ±0.03 °C at 0 °C, ±0.08 °C at 100 °C. Reference quality.

Precision Plus is supplied with a 17-160222 PT100 Class 1/10 DIN liquid probe — 10 times better precision than standard Class B.

Practical consequence: a Thermapen with ±0.4 °C precision can be verified against a 1/10 DIN PT100 with ±0.03 °C — a calibration uncertainty ratio of 4:1, which is the standard requirement for valid calibration according to ILAC guidelines.

5-point UKAS calibration certificate

UKAS (United Kingdom Accreditation Service) is the British equivalent of SWEDAC. UKAS certificates are internationally recognized via ILAC (International Laboratory Accreditation Cooperation) and accepted by all ISO 9001 auditors in the EU.

The 5-point certificate contains calibration data at 5 temperature points (typically -20, 0, 20, 60, 100 °C). This is sufficient to characterize the instrument’s accuracy over its entire operating range with interpolation between points.

The certificate documents for each point:

  • Reference temperature (from the calibration lab).
  • Instrument reading.
  • Deviation (reference − instrument).
  • Expanded uncertainty (typically ±0.03–0.05 °C).

With this certificate, the operator can verify INDIVIDUAL thermometers by placing both in the same reference medium (typically ice-water for the 0 °C point, boiling water for the 100 °C point) and comparing the readings.

Practical calibration workflow with Precision Plus

Daily: Ice-water verification

  1. Fill an insulated beaker with crushed ice + distilled water (50/50).
  2. Wait 2–3 minutes for temperature stabilization.
  3. Immerse both the Precision Plus and the test instrument in the ice-water.
  4. Read both after 30 seconds to 1 minute.
  5. Calculate the deviation. If > ±0.5 °C, note for trend analysis or service the instrument.

Weekly: Multi-point verification

  1. In addition to ice-water (0 °C), verify at room temperature (~20 °C) and a hot reference (e.g., boiling water adjusted for local air pressure, typically 99 °C).
  2. Trend analysis over weeks shows if the instrument is drifting.

Monthly: Documented calibration report

  1. Formal report with Precision Plus reference values + test instrument readings + calculated deviations.
  2. The report documents validity for the entire month.
  3. Archived according to quality system requirements.

Annually: External re-certification of Precision Plus

Precision Plus is returned to a UKAS lab (or equivalent SWEDAC lab in Sweden) for a new 5-point verification. A new certificate is obtained, valid for 12 months.

Economic analysis

Without Precision Plus (external calibration per instrument):

  • 10 Thermapens × 1,500 SEK = 15,000 SEK per year.
  • All instruments out of operation for 2–3 weeks per year.
  • Backup instruments required.

With Precision Plus (internal calibration):

  • Precision Plus purchase: 3,460 SEK.
  • Annual re-certification of Precision Plus: 1,500 SEK.
  • No external calibration of routine instruments required (only internal verification).
  • Annual operating cost: 1,500 SEK after the first year.

Break-even time: approximately 3–4 months with 10 instruments. After that, Precision Plus is dramatically more economical.

Open circuit Err indication and battery status

Precision Plus has visual indication for error states:

  • “Err” on display: Open circuit — PT100 probe not connected or cable break. Prevents incorrect readings from a misconfigured instrument.
  • Low battery indication: Blinking battery symbol when AAA battery capacity is below 10 %. Weak batteries can affect the precision of the reference measurement.

Battery life: at least 2,000 hours (~5–6 months with daily 12-hour use).

BioMaster antimicrobial plastic

The instrument’s plastic body is manufactured with BIOMASTER antimicrobial technology. Silver ions embedded in the plastic kill bacteria that come into contact with the surface.

Critical for use in:

  • Food industry (HACCP environment).
  • Hospital and pharmaceutical production.
  • Vaccine and drug manufacturing.
  • Catering and restaurant kitchens.

Complies with EN 13485 (medical equipment standard) for quality management systems.

Replaceable probe connection

The standard probe included is the 17-160222 liquid probe (Ø3 mm × 100 mm, for immersion in liquid baths for calibration). Other probes can be used via the Lumberg connector:

  • Surface probe (surface temperature for validation of surface thermometers).
  • Fast needle probe (for short-insertion calibration).
  • Long needle (for deep-insertion calibration in larger vessels).
  • Air probe (for validation of air thermometers).

Note: the specified ±0.03 °C precision is for the INSTRUMENT plus 1/10 DIN probe combination. When switching to another probe (e.g., thermocouple), the precision decreases.

Calibration test lock accessories

ETI also offers CALIBRATION TEST LOCKS that close over the Precision Plus probe for point verification. Standard variants:

  • Ice point reference (holds 0 °C in cell).
  • Multi-point fixed references (metal phase transition standards).

This allows Precision Plus to be used BOTH as a reference AND as a verified instrument without needing external ice baths or boiling equipment.

Applications

HACCP food industry: Standard verification of all facility thermometers (Thermapen, ThermaGuard, DishTemp).

Pharmaceutical production: GxP requirements for calibration verification of all temperature-monitored production processes.

Cold chain verification: Reference for validation of all loggers in cold storage, transport, and final receiving points.

Calibration labs (External): Even dedicated calibration labs use Precision Plus as a WORKING REFERENCE for field work outside the primary lab.

Healthcare — vaccine cold chain: Regional vaccine centers use it for verification of vaccine refrigerator thermometers.

Brewery: Beer fermentation temperature loggers are validated periodically.

Cheese and dairy production: Cheese ripening room temperature logging is validated.

Textile dyeing: Dye bath temperature (critical for color uniformity).

Chemical synthesis: Reaction temperature monitoring in synthesis labs.

Training facilities: Vocational training in quality measurement uses Precision Plus as a demo instrument.

Alternatives in the precision reference category

Precision Plus (this one): 3,460 SEK. ±0.03 °C. Good for business-internal calibration.

Fluke 1523/1524 Reference thermometer: 15,000–25,000 SEK. ±0.015 °C. For dedicated calibration labs.

Hart Scientific 1502A Tweener: 30,000–45,000 SEK. ±0.006 °C. Absolute top-tier.

Fixed-point cells (ice, gallium, indium): 5,000–30,000 SEK per cell. Fundamental reference directly traceable to ITS-90.

Fluke 9142 Field calibrator bath: 50,000–80,000 SEK. Dry-block calibrator for multi-points -25 to +150 °C.

Specifications

  • Instrument accuracy: ±0.03 °C (specified for the entire measurement range).
  • Resolution: 0.01 °C.
  • Measurement range: -100 to +250 °C (standard range, can be extended with special probes).
  • Probe: 17-160222 PT100 1/10 DIN Class A liquid probe, Ø3 mm × 100 mm.
  • Probe connection: Lumberg connector (can be swapped with other probe variants).
  • Display: large LCD with backlight.
  • Functions: Max/Min, Hold, °C/°F.
  • Battery: 3 AAA (1.5V), 2,000+ hours life.
  • Automatic shutdown after 10 min (can be disabled).
  • Open circuit Err indication.
  • Low battery indication.
  • Body: BioMaster antimicrobial plastic, EN 13485 compatible.
  • Supplied with 5-point UKAS calibration certificate.

What you get for the money

ETI Precision Plus PT100 reference thermometer, including 17-160222 PT100 1/10 DIN Class A liquid probe (Ø3 mm × 100 mm), ±0.03 °C accuracy, 5-point UKAS calibration certificate (valid 12 months), large LCD display, Lumberg connector for probe change, Max/Min/Hold functions, BioMaster antimicrobial plastic body EN 13485, 3 AAA batteries with 2000+ h life, automatic shutdown. 3,460 SEK.

The standard reference tool for all businesses that have multiple temperature meters and quality system requirements for calibration verification. The premium over a standard Thermapen is dramatically justified when the business has 5+ thermometers — instead of annual external calibration of all, internal verification against Precision Plus is sufficient, which itself is calibrated externally every 12th month.

Read more: ETI Precision Plus PT100 in the shop →

More news

All news