Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableThe temperature was right at the loading dock, but what happened during transport?Fridge air temperature doesn’t tell you how warm the product is: how to measure what actually mattersVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to know your thermometer reads correctly: check your own instruments against a reference with ±0.03 °C accuracyThe fridge never alarmed last night: how to detect temperature deviations before your goods are ruinedThe glare on the shiny surface hides the crack: how to see and measure the defect without guessingCarbon Dioxide Levels Reveal the Ventilation That Temperature Never ShowsWith 0.4-second readings, temperature checks become something you actually have time to doSee the fault behind the wall without having to take anything apart firstThe fault only showed up on Monday: how a humidity log reveals what happened over the weekendFind the fault in the electrical cabinet with a thermal camera before you put the current clamp on the cableThe temperature was right at the loading dock, but what happened during transport?Fridge air temperature doesn’t tell you how warm the product is: how to measure what actually matters
Item number 52-IRIS-PLUS

IRIS Intelligent refractometer probe for various substances – Directly mounted in the flow process

Call for price

In stock

The IRIS process refractometer connects directly to industrial flows and indicates various concentrations in liquids….

Request a quote 52-IRIS-PLUS
  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments for professionals since 2002
  • Call us +46 8 753 00 04

Category:

Description

How does an Inline refractive index probe differ from an Inline refractometer?

Inline refractometers are, for the most part, best described as a “dumb sensor” connected via cable to an external controller. The proprietary control cabinet typically houses a display, which the user interacts with, and connections to external equipment, such as PLCs, computers, or other data acquisition units. Mounting the control box near the probe takes up space, increases installation time, incurs additional costs, and adds another item to maintain or replace. There are generally few plumbing options because the Dumb Sensor is usually installed in the main process flow and often requires special, often expensive, adapters.

The Dumb Sensor/Control Box model is a throwback to earlier days. In the new world of digital controls, few people look at the screen on the control panel. Most users simply want to connect a probe to their network and read the measurements on their computer, HMI, or SCADA equipment. There is really no need for an external display in most installations.

Unlike conventional inline or process refractometers, the IRIS Inline probe is a true “smart sensor” that operates completely independently of an external control unit. The IRIS Inline is designed to connect directly to your control system with an analog 4 to 20 mA or 0 to 10 volts output (digital RS232 output is an option). In the event that you need a digital display, a low-cost bench meter can be added.

Flexible installation

As the name suggests, most inline refractometers are mounted “inline” with a process flow. Inline fittings often require special, often expensive, custom adapters, and the entire process must be shut down to remove part of the sensing head for cleaning or maintenance. The IRIS Inline probe is easily connected to a bypass flow, in parallel with the main process, using common off-the-shelf hardware.

Instead of a sensor that forces you to adapt your process to the sensor, the MISCO IRIS Sensor is easily integrated into your process. Two push-to-connect I/O ports on the front of the flow-through adapter make it simple to connect the IRIS sensor to almost any type of process. These 5/16″ (8mm) ports accommodate an almost unlimited number of common, inexpensive, ready-made connectors and adapters.

Here are just a few connector options:

• 5/16″ flexible tubing can be run straight into one of the push-to-connect I/O ports and out through the other.

• Two right-angle elbows, one short and one long, can be inserted into the I/O ports and provide 360° rotation so that lines can come in from all angles.

• The 5/16″ push-to-connect adapter can expand to accept 3/8″ flex tubing and can reduce to ¼”, 3/16″, or 5/32″ tubing.

• The 5/16″ push-to-connect adapter converts to 1/8″ or ¼” NPT-M, 10-32 UNF, BSPT or BSPP.

• The ¼” NPT-M mounting can connect with a number of sizes of NPT pipe fittings.

• 5/16″ push-to-tube fitting to ¼” tube nipple.

If you are running steel pipe, flexible tubing, hose, or tube, there is likely a quick push-to-connect adapter for your needs.

How to Install

Installation is quick and easy.

1. Screw the bracket to C-Channel, Unistrut, or another suitable location.

2. Run lines to flow through the adapter.

3. Run the sensor cable from the PLC or data acquisition unit to the sensor bracket.

4. Configure the sensor: When you first receive your IRIS, configure it to your needs with MISCO Inline Connect (included). Connect the sensor to the USB port on your computer and run the program. Configuration is very simple!

5. Connect the sensor and flow-through adapter. Requires a ¼ turn and locks into place. No tools needed.

6. Screw the sensor cable onto the back of the IRIS and you are ready to go.

*The sensor comes with a special configuration program. Requires a computer running the MS Windows operating system and a USB port.

Specification

How does an Inline refractive index probe differ from an Inline refractometer?

Inline refractometers are, for the most part, best described as a “dumb sensor” connected via cable to an external controller. The proprietary control cabinet typically houses a display, which the user interacts with, and connections to external equipment, such as PLCs, computers, or other data acquisition units. Mounting the control box near the probe takes up space, increases installation time, incurs additional costs, and adds another item to maintain or replace. There are generally few plumbing options because the Dumb Sensor is usually installed in the main process flow and often requires special, often expensive, adapters.

The Dumb Sensor/Control Box model is a throwback to earlier days. In the new world of digital controls, few people look at the screen on the control panel. Most users simply want to connect a probe to their network and read the measurements on their computer, HMI, or SCADA equipment. There is really no need for an external display in most installations.

Unlike conventional inline or process refractometers, the IRIS Inline probe is a true “smart sensor” that operates completely independently of an external control unit. The IRIS Inline is designed to connect directly to your control system with an analog 4 to 20 mA or 0 to 10 volts output (digital RS232 output is an option). In the event that you need a digital display, a low-cost bench meter can be added.

Flexible installation

As the name suggests, most inline refractometers are mounted “inline” with a process flow. Inline fittings often require special, often expensive, custom adapters, and the entire process must be shut down to remove part of the sensing head for cleaning or maintenance. The IRIS Inline probe is easily connected to a bypass flow, in parallel with the main process, using common off-the-shelf hardware.

Instead of a sensor that forces you to adapt your process to the sensor, the MISCO IRIS Sensor is easily integrated into your process. Two push-to-connect I/O ports on the front of the flow-through adapter make it simple to connect the IRIS sensor to almost any type of process. These 5/16″ (8mm) ports accommodate an almost unlimited number of common, inexpensive, ready-made connectors and adapters.

Here are just a few connector options:

• 5/16″ flexible tubing can be run straight into one of the push-to-connect I/O ports and out through the other.

• Two right-angle elbows, one short and one long, can be inserted into the I/O ports and provide 360° rotation so that lines can come in from all angles.

• The 5/16″ push-to-connect adapter can expand to accept 3/8″ flex tubing and can reduce to ¼”, 3/16″, or 5/32″ tubing.

• The 5/16″ push-to-connect adapter converts to 1/8″ or ¼” NPT-M, 10-32 UNF, BSPT or BSPP.

• The ¼” NPT-M mounting can connect with a number of sizes of NPT pipe fittings.

• 5/16″ push-to-tube fitting to ¼” tube nipple.

If you are running steel pipe, flexible tubing, hose, or tube, there is likely a quick push-to-connect adapter for your needs.

How to Install

Installation is quick and easy.

1. Screw the bracket to C-Channel, Unistrut, or another suitable location.

2. Run lines to flow through the adapter.

3. Run the sensor cable from the PLC or data acquisition unit to the sensor bracket.

4. Configure the sensor: When you first receive your IRIS, configure it to your needs with MISCO Inline Connect (included). Connect the sensor to the USB port on your computer and run the program. Configuration is very simple!

5. Connect the sensor and flow-through adapter. Requires a ¼ turn and locks into place. No tools needed.

6. Screw the sensor cable onto the back of the IRIS and you are ready to go.

*The sensor comes with a special configuration program. Requires a computer running the MS Windows operating system and a USB port.