Published 12 October 2026 at 14:05
It is Monday morning and a pallet of moisture-sensitive material has started to show stains. The hygrometer on the wall shows normal values now, but no one knows what the climate was like over the weekend. Without a log, it is impossible to document what happened or to know whether the rest of the warehouse is affected.
What the ThermaData HTDF is
The HTDF is a data logger that measures both temperature and relative humidity. The temperature range is -20 to 85 °C and the humidity range is 0 to 100 % RH. The probes are external, which means the measuring point can be placed where the problem is while the logger itself sits in an easily accessible location. The logger has an LCD display that alternates between temperature and humidity, and the memory holds 16,000 readings, divided into 8,000 per quantity.
What problems it solves
A single read value only shows the moment. The logger records the progression at an interval that you program yourself, and two LEDs show the status at a glance. A flashing green LED means the logger is active. A flashing red one means your preset alarm limits have been exceeded, so a deviation is visible during a quick inspection even if no one has opened a report. Data is transferred via USB-C, and the free software generates reports.
Where it is used
In warehouses for paper, wood or packaging, humidity determines how the material behaves. There, it is often enough to see that the level has been above the limit for a number of hours to determine which batches need to be checked.
In electronics production and assembly, moisture-sensitive components and materials with climate requirements are handled. A log showing that the environment has stayed within specification is concrete documentation for an internal audit or a customer review.
In the food industry and HVAC climate monitoring, the logger is used in cold storage and warehouse areas and in buildings where comfort or technical systems depend on stable conditions, respectively. Quality control is a stated area of use for the series.
Why it pays off
The cost of a missed deviation is rarely the instrument itself but what gets scrapped, reworked or becomes impossible to defend afterwards. In addition, the logger replaces manual rounds with a thermometer and hygrometer, which do not cover nights and weekends anyway. A deviation that would otherwise have been discovered after several days is visible with time and duration.
Keep in mind that humidity sensors are sensitive. Solvents and saturated air can contaminate them, and the sensor’s readings can drift by up to 0.5 % per year. Therefore, plan for recurring checks. A optional 3-point UKAS certificate at 25, 50 and 75 % RH is available for the logger, at a favorable price if ordered together with the logger.
If you need to be able to show what the climate has actually been like, and not just what it is right now, a logger with alarm indication is a simple way to get that documentation.