TandD Wireless 3-Channel Logger for CO₂, Temperature and Humidity with External High-Precision Sensor (SHA-3151). CO₂ 0–9 999 ppm, −25 to +70 °C, 0–99 %RH. Alarm Output. Range up to 150 m

8.350 kr

TandD Wireless 3-Channel Logger for CO₂, Temperature and Humidity with External High-Precision Sensor (SHA-3151). CO₂ 0–9 999 ppm, −25 to +70 °C, 0–99 %RH. Alarm output. Range up to 150 m

 

Description

The 56-RTR-576-S is TandD’s specialized air quality logger — measuring carbon dioxide concentration (CO₂), temperature, and humidity in a single unit, featuring high-precision sensors for T/RH that provide a wider measuring range and better accuracy than the standard model.

Designed for workplaces, classrooms, conference rooms, healthcare facilities, and indoor climate monitoring where elevated CO₂ levels can indicate insufficient ventilation and affect concentration, drowsiness, and well-being. The built-in automatic calibration function ensures reliable measurements over long operating cycles without manual adjustment. The measuring range of 0–9,999 ppm covers both normal office environments (~400–1000 ppm) and critical thresholds (1000 ppm = fatigue, 2000 ppm = significant discomfort).

Features

  • Measures CO₂, temperature, and humidity simultaneously in 3 channels
  • CO₂ measuring range: 0 to 9,999 ppm
  • Automatic calibration — maintains accuracy over time
  • S-model: temperature -25 to +70 °C, humidity 0 to 99 %RH
  • T/RH accuracy: ±0.3 °C / ±2.5 %RH (at 15–35 °C, 30–80 %RH)
  • Wireless range approx. 150 meters line of sight
  • Memory for 8,000 data points
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Built-in LCD with alternating display of all 3 channels
  • Bluetooth 4.2 BLE for configuration via mobile app

Specification

Measuring channels CO₂, Temperature, Humidity — 1 channel each
CO₂ measuring range 0 to 9,999 ppm
Temperature measuring range -25 to +70 °C (S-model)
Humidity measuring range 0 to 99 %RH (S-model)
T/RH accuracy ±0.3 °C / ±2.5 %RH (at 15–35 °C, 30–80 %RH)
Special function Automatic CO₂ calibration
Logging capacity 8,000 data points
Wireless communication EU: 869.7–870 MHz, RF power 5 mW, range approx. 150 m
Power supply Lithium battery LS14250 × 1
Battery life Approx. 10 months
Compatible base units 56-RTR500BC, 56-RTR500BW, 56-RTR500BM (each RTR-576 counts as 2 registrations)

Applications

The 56-RTR-576-S is selected for indoor climate and workplace monitoring where CO₂ is a critical parameter: schools and classrooms (elevated CO₂ linked to reduced learning), offices and conference rooms, healthcare facilities and hospitals, ventilation system monitoring, greenhouses with controlled CO₂ atmospheres, and vehicle test environments. Also useful in the food industry (fermentation processes, cold storage with controlled atmospheres). For light and UV measurement instead of CO₂, see the 56-RTR-574-S. For continuous CO₂ monitoring without a wireless base unit, see the 56-TR-76UI (USB connection to PC).

Additional information

Product type

Measures

% Relative Humidity, Carbon Dioxide CO2, Temperature

Communication

Wireless Long Range