Hoppa till innehåll
Free shipping over 5.595 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A red or green light shows whether the cold chain held all the waySeeing the fault inside the pipe costs less than opening the wall to look for itThe dishwasher shows 82 degrees, but what temperature does the plate actually reach?The temperature difference between two points often says more than two separate readingsThe Bearing Doesn’t Sound Wrong Until It’s Too Late – Measured and Logged Vibration Reveals the Fault Weeks EarlierWhen the temperature changes faster than the thermometer can respond, the check becomes guessworkHow to Tell if a Wire Is Live Without Touching the MetalThe temperature was right at closing time, but what happened during the night?See inside the engine block, duct or machine without taking anything apartSurface temperature at goods reception can be measured in three seconds without touching the productVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A red or green light shows whether the cold chain held all the waySeeing the fault inside the pipe costs less than opening the wall to look for itThe dishwasher shows 82 degrees, but what temperature does the plate actually reach?The temperature difference between two points often says more than two separate readingsThe Bearing Doesn’t Sound Wrong Until It’s Too Late – Measured and Logged Vibration Reveals the Fault Weeks EarlierWhen the temperature changes faster than the thermometer can respond, the check becomes guessworkHow to Tell if a Wire Is Live Without Touching the MetalThe temperature was right at closing time, but what happened during the night?See inside the engine block, duct or machine without taking anything apartSurface temperature at goods reception can be measured in three seconds without touching the product

A red or green light shows whether the cold chain held all the way

Published 27 November 2026 at 11:32

A pallet arrives at the loading dock. The cartons feel cold, the thermometer in the cargo area shows the right value at this moment, and the driver assures you that everything went fine. But nobody knows what the temperature was last night, during the break at the ferry, or when the refrigeration unit was off for an hour. It is a situation most people in food, pharmaceuticals and warehousing will recognize, and a momentary reading does not answer the question.

ETI ThermaData® Lite temperature logger – Blue. Shows whether temperature limits have been reached. USB-C connection. Free software for reports

What ThermaData Lite is

ThermaData Lite is a stand-alone temperature logger, sometimes called a blind recording thermometer. It sits in the load or on the shelf and records the ambient temperature at its own pace. The housing is made of water-resistant polyethylene and the logger has two LEDs. It is programmed via USB-C using the free ThermaData Studio software.

The problem it solves

The practical advantage of the Lite model is that you do not need a computer for the initial assessment. You set high and low alarm values in the software. After that, a press of the button is all it takes: if the green LED flashes, the limits have been kept; if the red one flashes, they have been exceeded. The recipient can then decide on the spot whether the goods need closer inspection, and you read the actual curve later.

The logging interval can be set from 6 seconds to 255 minutes, and the start can be delayed by up to 23 hours and 59 minutes, or triggered by a button press, at a certain temperature or at a certain time. With a 31-character user ID you can label the logger with, for example, an order number. The software also has a password-protected function for checking the calibration and adjusting in steps of 0.1 °C (±3 °C).

Three situations where it comes in useful

Food production and commercial kitchens. The logger travels with a delivery of chilled or frozen goods, or sits in a cold room over the weekend. The housing is available in blue, yellow, white and black, so you can assign one color per product group or department and reduce the risk of mix-ups and cross-contamination.

Pharmaceuticals and laboratories. Samples and reagents that must be kept within a temperature range can be shipped with a logger. The report from the software becomes part of the traceability.

Warehousing and transport. In the event of claims, a curve is something entirely different from an assertion. You can see when the deviation began, how long it lasted, and whether it happened before or after handover.

Why it pays off

The cost of a logger is small compared with the value of a single pallet that would otherwise be discarded as a precaution, or that is accepted even though it should have been stopped. You also save time: whoever receives the goods gets a clear answer in a few seconds, and in the event of a dispute there is documentation to present. Because the logger is easy to program and read, it can be used routinely and not only when something has already gone wrong.

If you want a simple way to document the temperature throughout the entire chain, ThermaData Lite is available from us. See the specification and order here.

Read more

More news