Two thermometers hang in the same cold room and read 3.1 and 4.6 °C. Nobody knows which one is right, but the auditor is asking for documentation and production is waiting for an answer. This situation is common in quality work, and it arises because most temperature instruments are used for years without their deviation ever being checked.
What a reference thermometer is
The ETI reference thermometer is an instrument used as the benchmark when other thermometers are to be checked. It has a permanently attached PT100 probe in class 1/10 DIN and a system accuracy of ±0.03 °C between -49.99 and +149.99 °C. Outside that range, down to -199.99 and up to +199.99 °C, the accuracy is ±0.1 °C. The resolution is 0.01 °C. It is supplied with a UKAS calibration certificate with five check points, so the measurement chain is documented all the way back.
The problem it solves
A typical handheld instrument often has a specified accuracy of ±0.5 °C or worse, and it drifts over time. Without a reference, it is impossible to determine whether a deviation is due to the instrument, the probe, or the temperature actually differing between two locations. With a reference thermometer you get a comparison value that is a couple of orders of magnitude better than the one you are checking.
When and how it is used
The method is called comparative calibration checking. The probe from the instrument being checked and the reference probe are placed together in the same stable temperature, for example an ice bath at 0 °C, a stirred liquid bath or a dry block. Once the values have stabilised, you read off the difference and document it. If you do this at regular intervals, drift becomes visible before it turns into a problem.
Three areas of use
Food production: Self-inspection relies on probe and refrigeration thermometers reading correctly. With a reference, the quality manager can check the entire inventory in-house before an audit, instead of sending all the instruments away at the same time.
Laboratory: Incubators, water baths and sample refrigerators require documented temperature. The reference thermometer provides an independent check value that can be compared against the chamber’s own display.
Workshop and maintenance: Where hardening furnaces, oil baths or coolants are monitored with fixed probes, a reference can reveal a probe that is drifting before it affects the process or leads to scrapped parts.
Why it pays off
External calibration of every individual instrument costs both money and downtime, since the instrument is away for weeks. With a reference you do the checking yourself and only send away the instruments that actually deviate. It also reduces the risk of wrong decisions, such as scrapped goods that were actually within the limit, or approved goods that were not. The reference itself needs to be recertified at set intervals, but it is a single instrument instead of many. Please note that the product is calibrated when ordered, so the delivery time is 10 to 14 days.
If you want a clear and traceable basis for all temperature measurements in your operation, the reference thermometer is available here: ETI Reference thermometer with PT100 probe.